The aim of this research, carried out with the Faculty of Engineering of UMons, was to determine the bearing capacity at the support of a CLT panel notched over more than half its depth. This notch was needed to meet the various constraints of a renovation project.
Lund University carried out a research campaign on 160 mm CLT panels notched at the support. It showed that when the notch exceeds 0.5h, the formula given in EC5 no longer applies. Research on this topic is ongoing and no calculation model yet exists for the case where hef < 0.5h. CLT notched beyond 0.5h therefore has to be tested in the laboratory. Tests were carried out with and without screw reinforcement.